ota | universal OverTheAir firmware update system
kandi X-RAY | ota Summary
kandi X-RAY | ota Summary
Universal OverTheAir firmware update system for esp-open-rtos based GitHub repositories. With release 0.3.0 this repository has finally migrated to LCM. If you are an early adopter Version 0.3.0 will make the switch over automatically once you trigger an OTA update You can monitor LCM using the terminal command on a mac on the same Wifi network as your device. Thanks for your interest.
Support
Quality
Security
License
Reuse
Top functions reviewed by kandi - BETA
Currently covering the most popular Java, JavaScript and Python libraries. See a Sample of ota
ota Key Features
ota Examples and Code Snippets
Community Discussions
Trending Discussions on ota
QUESTION
I am in step 3 of AWS OTA documentation https://docs.aws.amazon.com/freertos/latest/userguide/ota-code-sign-cert-esp.html
I am able to do the first two steps but not able to make the certificate:
...ANSWER
Answered 2022-Mar-22 at 07:45Try ./cert_config.txt in the parameter.
QUESTION
I'm trying to get root certificate for gitlab.com so that I can download files/build artifacts from repository using GitLab API (I need this due for HTTPS authentication from an IoT device).
For GitHub, I used the following command, provided by the MCU manufacture for OTA:
ANSWER
Answered 2022-Mar-02 at 08:26From issue 15364, you should be able to see the root CA (and 2 intermediate CAs) with:
QUESTION
I need to load a simple applet to my USIM card. Authentication is OK. I'm using OTA SMS-DELIVER via SmartCard to install CAP file.
Using these:
I couldnt find the right spec explaining "C482XXYY" in Header.cap, how it should be calculated,
this answer below helped me navigate, but for Method.cap loading - it still fails https://community.oracle.com/tech/developers/discussion/1753814/globalpaltform-load-command-data-field
I've written this loader: https://pastebin.com/pSXeDYyS
Every component in CAP file is in separate APDU with LOAD instruction. First 5 is loaded successfully with DATA=00, SW=9000, however on Method it fails. As you can see from my script, I've fixed Descriptor size to 0000 in Directory field. And in Header C482xxyy, where xxyy is calculated properly, which is a sum of all size fields in Directory, e.g.
...ANSWER
Answered 2022-Feb-07 at 01:35You can have a look into the GlobalPlatform project loader. It is LPGL, so directly using it as C code in other non LGPL projects is not possible.
[!!!!] LOAD - Method (FAILED)
80e800057007006d000911188c00048d00012c18197b0002037b00029210240303038b000388007a02318f00053d8c00062e1b8b00077a0120188b000860037a7a02228d00092d1d10076b101a8b000a321fae006b06188c000b7a06118d000c2c1903077b000d037b000d928b000e198b000f3b7a00c0000000
<< 9000 (should be 009000)
I assume that the log is the unwrapped logged before the commands are prepared for SCP80. A response of 9000 in OTA means usually "I received the command, but I don't know what to do with it". Is this 9000 command from the ENVELOPE response on the card? Are you sending the data over an SMPP connection?
Can you try your loading code with a simple HelloWorld Applet without any STK? It could be that your card is not supporting a version you are linking against, e.g. different ETSI releases. Then some method might not be supported and the loading fails.
QUESTION
I am very new to React Native and Expo. I am now assigned to work on our company mobile app. While doing a build and pushing to Test Flight in Apple Connect, I noticed that my test code is getting Over the Air updated and going live. This is a big problem.
How do I tell from where my app is getting updated live?
I am using the Expo build tools. I checked the configuration for updates in the expo section of the app.json
file. It looked like this:
ANSWER
Answered 2022-Feb-02 at 07:19The reason you are seeing the updates to your production app is because each time you create a new build, expo "publishes" your latest build which pushes any changes OTA to all users unless you use 'release channels'.
Here is the expo documentation supporting the above statement:
https://docs.expo.dev/classic/building-standalone-apps/#3-start-the-build
"Please note: When you run expo build
, Expo automatically publishes your app (with expo publish
). In order to avoid accidentally publishing changes to your production app, you may want to use release channels."
https://docs.expo.dev/distribution/release-channels/
Once you establish a release channel separate from your production build, you can build separately, and publish OTA updates to that separate build apart from your app that is already live.
This may go without saying, but you can revert your production app using expo publish
. As it stands with your current release channel setup, this will also update your TestFlight app.
QUESTION
I have installed multiple versions of .NET Sdk.Now the Omnisharp suggestions is not working fine.
output shows these
...ANSWER
Answered 2022-Jan-26 at 23:55See the documentation here https://github.com/OmniSharp/omnisharp-vscode
Using .NET 6 builds of OmniSharp Starting with C# extension version 1.24.0, there is now an option to use build of OmniSharp that runs on the .NET 6 SDK. This build requires that the .NET 6 SDK be installed and does not use Visual Studio MSBuild tools or Mono. It only supports newer SDK-style projects that are buildable with dotnet build. Unity projects and other Full Framework projects are not supported.
To use the .NET 6 build, set
omnisharp.useModernNet
totrue
in your VS Code settings and restart OmniSharp.
QUESTION
I am trying to send the 128
bytes of the block to BLE Controller using the RxAndroidBle
library. the flow to send data from mobile to BLE controller is as follows
- Connect with BLE Controller
- Start OTA (sending 1)
- Send CRC (of the data block)
- Send data block
- wait for 2 seconds
- repeat step 3
- END OTA (sending 2)
Here is snapshot of a code
...ANSWER
Answered 2022-Jan-02 at 10:07You can use flatMapIterable()
with toList()
. Try to add toList()
operator before OTA_DATA_END
command like:
QUESTION
When I run the jq command to parse a json document from the amazon cli I have the following problem.
I’m parsing through the IP address and a tag called "Enviroment". The enviroment tag in the instance does not exist therefore it does not throw me any result.
Here's an example of the relevant output returned by the AWS CLI
...ANSWER
Answered 2021-Dec-15 at 21:34You can either use an if ... then ... else ... end
construct, or //
. For example:
QUESTION
I have written a Python script utilizing the Python-CAN library which records received CAN messages at a 1 second rate for 5 minutes, before logging all the messages into a file and exiting. The computer has a CAN module which is connecting to the CAN bus. (The other device on the bus is an engine) I communicate with it using the SocketCAN interface.
The test engine system that this computer is connected to is sending around 114 messages at what I believe is a 250kb baud rate. I am expecting to see 114 messages recorded in the file for each 1 second period, but instead I'm seeing about half that count. (~65 messages)
Could it be possible that the engine's ECU is set to a 500kb baud rate, and that's why I'm not getting the count I am expecting? I would think there would be no communication if the baud rates do not match, but I do not have physical access to the system because I'm sending the script remotely through an OTA update and not running it myself. (The device is headless, but is setup to run the script on startup) I just see the log files that are generated.
Here is the python code:
(A note, I have code parsing the received messages into the contained signals, but I did not include this code here because it happens at the end, and it is not relevant)
...ANSWER
Answered 2021-Dec-09 at 12:05In my experience, most of the engine's ECU usually uses 250kb, but the newest ones are using 500kb. I would suggest you too also try the both.
Also, the messages will only come to the bus if they have been sent, it seems silly but for example a truck, if you don't step on the accelerator the messages referring to the accelerator will not appear. So, maybe you need to check if all components are being using as you expect. The lib of can-utils has a 'Can sniffer' that can also help you.
I suggest you to use 'can-utils' to help you in that. It is a powerful tool to can analyses.
Did you try to loop the baudrate? Maybe can also help to find another.
QUESTION
I've built an app with expo managed workflow but then we needed a native module to be added to the app so I generated native project files using expo run:[android | ios]
which works well on the development but I'm curious what could be the best approach to generate android release apk for the current project?
If I follow the expo build:[android | ios]
I think my native changes won't be included in that build. But at the same time if I use gradlew assembleRelease
then I think I will lose the expo OTA updates.
Sorry if my question seems a mess but I really need some guidance following that approach.:
...ANSWER
Answered 2021-Dec-09 at 11:05Have you looked at Expo EAS - https://docs.expo.dev/build/introduction/
QUESTION
I'm trying to design an OTA update system and would like to use meta-swupdate with Yocto, here is what I did:
bitbake-layers add-layer ../meta-openembedded/meta-oe/
bitbake-layers add-layer ../meta-swupdate
bitbake-layer showlayers
ANSWER
Answered 2021-Aug-10 at 12:41Do not use the master
branch of https://github.com/sbabic/meta-swupdate
Use the branch that is compatible with your poky
branch. (dunfell, zeus, ...)
For example, in dunfell
branch it is fixed:
Community Discussions, Code Snippets contain sources that include Stack Exchange Network
Vulnerabilities
No vulnerabilities reported
Install ota
Support
Reuse Trending Solutions
Find, review, and download reusable Libraries, Code Snippets, Cloud APIs from over 650 million Knowledge Items
Find more librariesStay Updated
Subscribe to our newsletter for trending solutions and developer bootcamps
Share this Page