transmission | A GNOME 3.14 HIG-compliant Transmission | Navigation library
kandi X-RAY | transmission Summary
kandi X-RAY | transmission Summary
Transmission is a fast, easy, and free BitTorrent client. It comes in several flavors:. Visit for more information. Transmission has an Xcode project file (Transmission.xcodeproj) for building in Xcode. For a more detailed description, and dependancies, visit:
Support
Quality
Security
License
Reuse
Top functions reviewed by kandi - BETA
Currently covering the most popular Java, JavaScript and Python libraries. See a Sample of transmission
transmission Key Features
transmission Examples and Code Snippets
Community Discussions
Trending Discussions on transmission
QUESTION
I have a microcontroller which I communicate with my windows pc, through FT232RL. On the computer side, I am making a C-library to send and receive data, using windows API.
I have managed to:
- Receive data (or multiple receives),
- Transmit data (or multiple transmits),
- First transmit (or multiple transmits) and then receive data (or multiple receives)
But I have not managed to:
- Transmit Data and then receive.
If I receive anything, and then try to transmit, I get error. So, I guess when I receive data, there is a change in configuration of the HANDLE hComm
, which I cannot find.
So the question is, what changes to my HANDLE hComm
configuration when I receive data, which does not allow me to transmit after that?
Here is my code/functions and the main() that give me the error. If I run this, I get this "error 6" -screenshot of the error down below-:
...ANSWER
Answered 2021-Jun-14 at 01:17According to MSDN:Sample, Maybe you need to set a pin's signal state to indicate the data has been sent/received in your microcontroller program. More details reside in your serial communication transmission of data standard. And you should write code according to the result of WaitCommEvent(hCom, &dwEvtMask, &o);
like the linked sample.
QUESTION
According to Wikipedia, the ASCII is a 7-bit encoding. Since each address (then and now) stores 8 bits, the extraneous 8th bit can bit used as a parity bit.
The committee voted to use a seven-bit code to minimize costs associated with data transmission. Since perforated tape at the time could record eight bits in one position, it also allowed for a parity bit for error checking if desired.[3]:217, 236 §5 Eight-bit machines (with octets as the native data type) that did not use parity checking typically set the eighth bit to 0.
Nothing seems to mandate that the 8th bit in a byte storing an ASCII character has to be 0. Therefore, when decoding ASCII characters, do we have to account for the possibility that the 8th bit may be set to 1? Python doesn't seem to take this into account — should it? Or are we guaranteed that the parity bit is always 0 (by some official standard)?
ExampleIf the parity bit is 0 (default), then Python can decode a character ('@'):
...ANSWER
Answered 2021-Jun-12 at 11:39The fact that the parity bit CAN be set is just an observation, not a generally followed protocol. That being said, I know of no programming languages that actually care about parity when decoding ASCII. If the highest bit is set, the number is simply treated as >=128
, which is out of range of the known ASCII characters.
QUESTION
When calculating UDP checksums I know that we complement the result and use it to check for errors. But I don't understand why we use 1's complement instead of 2's complement (as shown here). If there are no errors 1's complement results -1 (0xFFFF) and 2's complement results 0 (0x0000).
To check for correct transmission, receiver's CPU must first negate the result then look at the zero flag of ALU. Which costs 1 additional cycle for negation. If 2's complement was used the error checking would be done simply by looking at the zero flag.
...ANSWER
Answered 2021-Jun-09 at 16:08That is because using 2's complement may give you a wrong result if the sender and receiver machines have different endianness.
If we use the example:
0000 1111 1110 0000 1111 0000 0001 0000
the checksum with 2's complement calculated on a little-endian machine would be:
0000 0000 0001 0000
if we added our original data to this checksum on a big-endian machine we would get:
0000 0000 1111 1111
which would suggest that our checksum was wrong even though it was not. However, 1's compliments results are independent of the endianness of the machine so if we were to do the same thing with a 1's complement number our checksum would be:
0000 0000 0000 1111
which when added together with the data would get us:
1111 1111 1111 1111
which allows the short UDP checksum to work without requiring both the sender and receiver machines to have the same endianness.
QUESTION
I've tried couple of weeks and searched for days for an answer, but haven't found it. My code is rather large and intertwined, but my problem is with 3 functions/classes, therefore I will only show my declarations and relevant information. I have the following non-compliable code:
...ANSWER
Answered 2021-Jun-08 at 09:22You want this:
QUESTION
This Microsoft Docs article shows how to configure SignalR in a Blazor app. There's a step there that adds the response compression middleware for the application/octet-stream
MIME type:
ANSWER
Answered 2021-Jun-07 at 08:03Could someone explain if and why this step is required? Does it make any significant difference? I suppose it is to optimize the transmission of binary messages over the SignalR connection.
The Response Compression Middleware is not required when using asp.net core SignalR in the Blazor. In this tutorial, if you remove the services.AddResponseCompression()
and app.UseResponseCompression();
in the Startup.cs file, the SignalR still works well.
More detail information, you could check the Response Compression Middleware, it is used to dynamically compress response bodies and reduce bandwidth utilization.
QUESTION
Please let me know. It is a sensor made by KEYENCE and is supposed to exchange ASCII. The specification states that, as an example, if you send such data, it will be received normally.
SR, 06,101 CRLF (ASCII) 0x53, 0x52, 0x2C, 0x30, 0x36, 0x2C, 0x31, 0x30, 0x31, 0x00, 0x0A (hexadecimal)
I created this example with python code and sent it. However, although the signal is being transmitted, an alarm is displayed and it seems that it is not being received normally. I wrote ASCII code transmission in python for the first time this time. Is there something wrong with the code? Thank you for your cooperation.
...ANSWER
Answered 2021-Jun-07 at 04:22Thank you very much. I replaced the raspberry pie and it was solved. This code worked fine. I apologize to you for a fuss over.
QUESTION
I'm a beginner in python so I have this program where it classifies tweets into different categories (sport,sante, culture...) using keywords and I would like to copy-paste every line of the JSON file that belongs to a certain category into a file named text1 and I did the following : but I guess I did it the wrong way since I keep receiving the same error please any suggestion on how to solve this problem!
...ANSWER
Answered 2021-Jun-06 at 22:54This might be a very simple case of fixing the encoding.
Your error says:
QUESTION
I am trying to establish a method of estimating infectious disease parameters by comparing real epidemic curves with simulations of a stochastic SIR model. To construct the stochastic SIR model, I am using the deSolve package and instead of using fixed parameter values I would like to draw the parameter value used in the equations at each time point from a Poisson distribution centered on the original parameter values.
Using the parameter beta as an example, beta represents the average number of transmission events per capita and is the product of the average number of contacts and the probability that transmission occurs upon contact. Realistically, there is variation in the number of contacts a person will have and since transmission is also a probabilistic event there is variation surrounding this too. So even if the average transmission rate were to be 2.4 (for example), an individual can go on to infect 0, 1, 2 or 3 ... etc. people with varying probabilities.
I have tried to incorporate this into my code below using the rpois function and reassigning the parameters used in the equations to the outputs of the rpois.
I have run my code with the same initial values and parameters multiple times and all the curves are different indicating that SOMETHING "stochastic" is going on, but I am unsure whether the code is sampling using the rpois at each time point or just once at the beginning. I have only started coding very recently so do not have much experience.
I would be grateful if anyone more experienced than myself could verify what my code is ACTUALLY doing and whether it is sampling using rpois at each time point or not. If not I would be grateful for any suggestions for achieving this. Perhaps a loop is needed?
...ANSWER
Answered 2021-May-31 at 18:14The code given in the question runs the model with constant parameters over time. Here an example with parameters varying over time. However, this setting assumes that for a given time step, the parameters are equal for all indidividuals of the pupolation. If you want to have individual variability, one can either use a matrix formulation for different sub-populations or use an individual model instead.
Model with fluctuating population parameters:
QUESTION
I am using tabula-py to read my class timetable PDF file in python and the return value 'data' has a lot of 'nan' values that I cannot seem to clean. Can someone suggest a solution? Should I be using something instead of tabula-py? I've attached a link to the picture of the PDF. I have redacted some info from the PDF for privacy.1
My code is as follows:
...ANSWER
Answered 2021-May-31 at 12:34I figured it out.
I realised, the problem was that the library was not reading the separations between the lines properly, so I set 'lattice=True'.
This solved my problem about 50% and realised the program requires greater specificity.
Downloaded Tabula for windows and found the coordinates of the entire table and also the separate columns. Fed that data into tabula-py under build options of 'area=' and 'columns=' .
I realise using both attributes is probably overkill, but upon formatting into .csv, all my data is neatly placed in separate columns with no 'Nan' values.
Attaching my code below:
QUESTION
I was trying to do a car transmission type input validation, but why does it keep saying invalid input although I have entered the right input (M/A)?
...ANSWER
Answered 2021-May-28 at 15:45You need to use and
, not or
.
This will solve your problem and give the desired result.
Community Discussions, Code Snippets contain sources that include Stack Exchange Network
Vulnerabilities
No vulnerabilities reported
Install transmission
Support
Reuse Trending Solutions
Find, review, and download reusable Libraries, Code Snippets, Cloud APIs from over 650 million Knowledge Items
Find more librariesStay Updated
Subscribe to our newsletter for trending solutions and developer bootcamps
Share this Page