golink | Link your go libraries , without the hassle | Build Tool library

 by   kofalt Go Version: v1.1.1 License: No License

kandi X-RAY | golink Summary

kandi X-RAY | golink Summary

golink is a Go library typically used in Utilities, Build Tool applications. golink has no bugs, it has no vulnerabilities and it has low support. You can download it from GitHub.

The simplest possible way to add libraries to your Go project. No environment variables, no config files, and your contributors won't even need to know about it.
Support
    Quality
      Security
        License
          Reuse

            kandi-support Support

              golink has a low active ecosystem.
              It has 7 star(s) with 5 fork(s). There are 2 watchers for this library.
              OutlinedDot
              It had no major release in the last 12 months.
              There are 2 open issues and 2 have been closed. On average issues are closed in 21 days. There are no pull requests.
              It has a neutral sentiment in the developer community.
              The latest version of golink is v1.1.1

            kandi-Quality Quality

              golink has no bugs reported.

            kandi-Security Security

              golink has no vulnerabilities reported, and its dependent libraries have no vulnerabilities reported.

            kandi-License License

              golink does not have a standard license declared.
              Check the repository for any license declaration and review the terms closely.
              OutlinedDot
              Without a license, all rights are reserved, and you cannot use the library in your applications.

            kandi-Reuse Reuse

              golink releases are available to install and integrate.
              Installation instructions are not available. Examples and code snippets are available.

            Top functions reviewed by kandi - BETA

            kandi has reviewed golink and discovered the below as its top functions. This is intended to give you an instant insight into golink implemented functionality, and help decide if they suit your requirements.
            • Main entry point for go - flags .
            • panicHandler handles panics .
            • WriteFile writes data to a file
            • Abs returns the absolute path .
            • CreateFolder creates a folder
            • Symlink is a wrapper around os . Symlink
            • Cause returns the error s cause .
            • ExitGently panics
            Get all kandi verified functions for this library.

            golink Key Features

            No Key Features are available at this moment for golink.

            golink Examples and Code Snippets

            GoLink,How?
            Godot img1Lines of Code : 9dot img1no licencesLicense : No License
            copy iconCopy
            $ golink create kofalt.com/example
            Creating example in package kofalt.com
            Building example...
            This is an example program generated by GoLink.
            
            $ golink add https://github.com/polydawn/pogo polydawn.net/pogo
            Adding polydawn.net/pogo from https://githu  
            GoLink,Features
            Godot img2Lines of Code : 2dot img2no licencesLicense : No License
            copy iconCopy
            $ ./goad help
            Usage: ./goad [init|build|clean|test|fmt|doc] [go packages...]
              

            Community Discussions

            QUESTION

            Link to kernel32.dll using ld.exe
            Asked 2021-May-14 at 02:16

            I have assembled my assembly program using the following command:

            nasm -f win64 -o test.obj test.asm

            test.asm contains a few functions that call Win32 functions like GetStdHandle, HeapAlloc, etc

            Normally, I would link one of my assembly projects like so:

            ld -LC:/Windows/System32 -lkernel32 -e main -o test.exe test.obj

            And it produces a test.exe file, as expected.

            However, once I begin to use Win32 functions making use of the heap, like HeapAlloc, HeapFree, GetProcessHeap, I get the following error when linking:

            C:\msys64\mingw64\bin\ld.exe: ertr000016.o:(.rdata+0x0): undefined reference to '_pei386_runtime_relocator'

            I was then able to assume it has to do with MinGW's files being linked in. So I tried to compile it without them:

            ld -nostdlib -nostartfiles -LC:/Windows/System32 -lkernel32 -e main -o test.exe test.obj

            and get the following error:

            C:\msys64\mingw64\bin\ld.exe: cannot find -lkernel32

            So, my question is: how am I supposed to link to kernel32 using ld.exe (without including startfiles or stdlib), because no matter what I try I cannot get it to work.

            Thank you for your help!

            (I would like an answer that doesn't just tell me use GoLink, please, unless that is the only possible solution).

            ...

            ANSWER

            Answered 2021-Feb-02 at 07:49

            QUESTION

            Nasm - Crinkler not importing winapi functions
            Asked 2020-Aug-21 at 08:42

            I've been trying to assemble this codeproject program with Nasm and Crinkler, but every time I try to link the object file with kernel32.lib and user32.lib it gives me the following output:

            ...

            ANSWER

            Answered 2020-Aug-21 at 08:42

            Fixed it!

            Just had to replace every extern "name" by an extern _"name"@"number" that I had to obtain by looking at kernel32.lib and user32.lib.

            Source https://stackoverflow.com/questions/63500508

            QUESTION

            How can I get a string from the global atom table?
            Asked 2019-Nov-26 at 02:05

            I've been trying to program in assembly for the windows OS for a few days now. I'm trying to store a string in the global atom table and getting it back afterwards.

            The problem is: When I call the function GlobalGetAtomNameA, the program crashes with code 5, access violation! Here's the code I wrote:

            ...

            ANSWER

            Answered 2019-Nov-26 at 01:57

            PUSH ax only pushes 16 bits but the calling convention passes narrow integers in a full 4-byte stack slot.

            Use movzx eax, word [...] loads of narrow data so you don't have to mess around with 16-bit operand-size.

            Then you can use push eax to push without garbage in the upper 2 bytes, in case your callee wants an int instead of a short. If it only looks at the low 2 bytes, it doesn't matter what was in the top half, but you definitely need push eax.

            Source https://stackoverflow.com/questions/59016552

            QUESTION

            Self page call doesn't update
            Asked 2019-Jan-28 at 21:08

            I'm trying to update a whole page in adf when you click on a link to go to the same page with new page parameters. If I open the link in a new tab, it works fine, but opening it in the same tab doesn't update.

            I have a page that just displays the parameter value from the url, a link to the same page with a different parameter value, and an output text that displays the datetime. My taskflow starts by calling RetrieveDateTime() and then goes to refrestTest.jsff. The taskflow is a region on refresh.jsf page.

            ...

            ANSWER

            Answered 2019-Jan-28 at 21:08

            I managed to solve this using the taskflow. Basically, I made the button go to a new page with a region. This region has a taskflow that reads the url parameters and if it matches my conditions, links back to the original page with new parameters (toDocumentsPage). Otherwise, goes to a different page (searchResults).Taskflow to refresh the page

            Source https://stackoverflow.com/questions/54096811

            QUESTION

            Unable to access array pointer passed to NASM 64 bit DLL
            Asked 2018-Jan-06 at 18:06

            I am passing pointers two arrays from a Python program (using ctypes) to a NASM 64-bit DLL. In the Windows calling convention, the pointers are passed in rcx and rdx. The two arrays are both Int64. The arrays are created in Python and passed to the DLL this way:

            ...

            ANSWER

            Answered 2018-Jan-06 at 18:06

            The solution proposed above by Michael Petch solved the problem. I removed "/entry SimpleTest" from the GoLink linker command string, as Michael proposed, and now I can both read from and write to from the arrays pointed to by rcx and rdx. The correct command string is:

            Source https://stackoverflow.com/questions/48122238

            QUESTION

            How to use Infinite scroll with Virtual scroll in Ionic 3?
            Asked 2017-Nov-15 at 07:08

            I'm new to ionic and angular,so having some trouble with using Infinite scroll with Virtual scroll.No data ie. images,text,click function are fetched from typescript when they are pushed in infinite scroll.Only empty ionic cards are shown.

            Code below FYI:

            HTML:

            ...

            ANSWER

            Answered 2017-Nov-15 at 07:08

            I think i found an answer to my question.May or may not work in your case.Anyway, i made changes in typescript code.Everything else is the same.No big differences from the question.

            TYPESCRIPT:

            Source https://stackoverflow.com/questions/47258999

            QUESTION

            Display images only after image is completely downloaded
            Asked 2017-Nov-10 at 11:50

            I'm building ionic 3 app which displays images in pages.The problem is the app is displaying images in an ugly manner, showing partial images loading from top to bottom.

            What I trying to achieve in this app is to display images only after fully downloaded preferably with a spinner.

            Here is the code i used:

            HTML:

            ...

            ANSWER

            Answered 2017-Nov-10 at 06:45

            You cannot use img tag inside the Virtual Scroll.It is not recommended by the Ionic team.

            HTTP requests, image decoding, and image rendering can cause jank while scrolling. In order to better control images, Ionic provides ion-img to manage HTTP requests and image rendering. While scrolling through items quickly, ion-img knows when and when not to make requests, when and when not to render images, and only loads the images that are viewable after scrolling

            But if you have an issue with ion-img then you need to use InfiniteScroll.You can bind the images to it after fetching all the images from the server.

            Source https://stackoverflow.com/questions/47216803

            Community Discussions, Code Snippets contain sources that include Stack Exchange Network

            Vulnerabilities

            No vulnerabilities reported

            Install golink

            You can download it from GitHub.

            Support

            For any new features, suggestions and bugs create an issue on GitHub. If you have any questions check and ask questions on community page Stack Overflow .
            Find more information at:

            Find, review, and download reusable Libraries, Code Snippets, Cloud APIs from over 650 million Knowledge Items

            Find more libraries
            CLONE
          • HTTPS

            https://github.com/kofalt/golink.git

          • CLI

            gh repo clone kofalt/golink

          • sshUrl

            git@github.com:kofalt/golink.git

          • Stay Updated

            Subscribe to our newsletter for trending solutions and developer bootcamps

            Agree to Sign up and Terms & Conditions

            Share this Page

            share link