stator | 😍🙏 | Web Framework library

 by   chocolat-chaud-io TypeScript Version: v1.19.2 License: MIT

kandi X-RAY | stator Summary

kandi X-RAY | stator Summary

stator is a TypeScript library typically used in Server, Web Framework, React, Boilerplate, Express.js applications. stator has no bugs, it has no vulnerabilities, it has a Permissive License and it has low support. You can download it from GitHub.

Have you ever started a new project by yourself? If so, you probably know that it is tedious to set up all the necessary tools. Just like you, the part I enjoy the most is coding, not boilerplate.
Support
    Quality
      Security
        License
          Reuse

            kandi-support Support

              stator has a low active ecosystem.
              It has 275 star(s) with 18 fork(s). There are 8 watchers for this library.
              OutlinedDot
              It had no major release in the last 12 months.
              There are 14 open issues and 53 have been closed. On average issues are closed in 177 days. There are 1 open pull requests and 0 closed requests.
              It has a neutral sentiment in the developer community.
              The latest version of stator is v1.19.2

            kandi-Quality Quality

              stator has no bugs reported.

            kandi-Security Security

              stator has no vulnerabilities reported, and its dependent libraries have no vulnerabilities reported.

            kandi-License License

              stator is licensed under the MIT License. This license is Permissive.
              Permissive licenses have the least restrictions, and you can use them in most projects.

            kandi-Reuse Reuse

              stator releases are available to install and integrate.
              Installation instructions, examples and code snippets are available.

            Top functions reviewed by kandi - BETA

            kandi's functional review helps you automatically verify the functionalities of the libraries and avoid rework.
            Currently covering the most popular Java, JavaScript and Python libraries. See a Sample of stator
            Get all kandi verified functions for this library.

            stator Key Features

            No Key Features are available at this moment for stator.

            stator Examples and Code Snippets

            No Code Snippets are available at this moment for stator.

            Community Discussions

            QUESTION

            How can i get information in between the indexes using regex?
            Asked 2020-Aug-27 at 13:03
            1. Icing of the engine and the leading edges of the intake duct can occur during flight through clouds containing supercooled water droplets or during ground operation in freezing fog. Protection against ice formation may be required since icing of these regions can considerably restrict the airflow through the engine, causing a loss in performance and possible malfunction of the engine. Additionally, damage may result from ice breaking away and being ingested into the engine or hitting the acoustic material lining the intake duct. 147 2. An ice protection system must effectively prevent ice formation within the operational requirements of the particular aircraft. The system must be reliable, easy to maintain, present no excessive weight penalty and cause no serious loss in engine performance when in operation. 3. Analyses are carried out to determine whether ice protection is required and, if so, the heat input required to limit ice build up to acceptable levels. Fig. 13-1 illustrates the areas of a turbo-fan engine typically considered for ice protection. 4. There are two basic systems of ice protection; turbo-jet engines generally use a hot air supply (fig. 13-2), and turbo-propeller engines use electrical power or a combination of electrical power and hot Ice protection Fig. 13-1 Areas t picall considered for ice protection. Fig. 13- Hot air ice protection. 148 149 Ice protection air. Protection may be supplemented by the circulation of hot oil around the air intake as shown in fig. 13-3. The hot air system is generally used to prevent the formation of ice and is known as an anti- icing system. The electrical power system is used to break up ice that has formed on surfaces and is known as a de-icing system. HOT AIR SYSTEM 5. The hot air system provides surface heating of the engine and/or powerplant where ice is likely to form. The protection of rotor blades is rarely necessary, because any ice accretions are dispersed by centrifugal action. If stators are fitted upstream of the first rotating compressor stage these may require 149 Ice protection protection. If the nose cone rotates it may not need anti-icing if its shape, construction and rotational characteristics are such that likely icing is acceptable. 6. The hot air for the anti-icing system is usually taken from the high pressure compressor stages. It is ducted through pressure regulating valves, to the parts requiring anti-icing. Spent air from the nose cowl anti-icing system may be exhausted into the compressor intake or vented overboard.

            How can I use regex to get 1. , 2. ... I tried using this but to no avail ^\d..*(?=\d.), it gives me everything

            ...

            ANSWER

            Answered 2020-Aug-27 at 13:03

            QUESTION

            PI-Controller doesn't reach reference value with inverter and PMSM in Modelica
            Asked 2019-Nov-06 at 09:41

            I'm trying to investigate the Modelica example Modelica.Electrical.Machines.Examples.SynchronousInductionMachines.SMPM_VoltageSource but I replaced the signalVoltage by an inverter and a PWM block signalPWM which is based on Modelica.Electrical.PowerConverters.DCDC.Control.SignalPWM. So instead of sine voltages I want to investigate PWM modulated voltages. The problem is that the controller keeps increasing its output linearily because of the integrating part of the controller as it never reaches the reference value of the desired q-current. In addition it outputs strange values for voltageController.y[1] in the range of [24E3,...,150E3], which is probrably the problem.

            The controller output:

            and the current output:

            Unfortunately I don't understand why the controller works fine with the sine voltages and doesnt with the PWM voltages.

            Below is my main model:

            ...

            ANSWER

            Answered 2019-Nov-06 at 09:41
            Original Answer

            With a voltage of ±200V and a load of 120Nm its simply not possible to obtain the demanded currents.

            In contrast to the original MSL example you use a sign torque with 120Nm as load. If you use that in the original MSL example, you will notice that the machine keeps accelerating and that the required voltage grows without bounds (plot e.g. smpm.plug_sp.pin[1].v to see that).

            In your example the voltage is limited to 200V. The demanded currents of -53A and 84.6A are not obtained, but the machine still generates a torque of 127Nm, which lets the machine accelerate. With increasing speed the required voltages increase also for a certain torque / current demand - but in your example the actual voltage is limited. Therefore the set currents are never reached.

            What you can consider:

            • increase the available voltage
              (but for the current setup you need unrealistic high values of several thousand volts)
            • demand lower currents
              (You can set Id on 0 anyway, as you have a machine with Ld=Lq, so only Iq produces torque and Id is used for field weakening)
            • make your current controllers aware of the voltage limit
              (use e.g. Modelica.Blocks.Continuous.LimPID for that, which contains anti-windup already)
            Updated Answer

            The problem lies in your PWM computation. I rebuilt the example with the original SignalPWM block from the MSL and a VoltageToDutyCycle component.

            In the screenshot below the simulation results of the new model with f=14kHz are compared with the MSL version with ideal voltage supply. The screenshot shows the controller output (like in your question) and Iq.

            The results were computed with the package below. It contains

            • a partial model for all common components and variables
            • an example with PWM and inverter
            • an example with ideal continuous voltage supply

            Note that the hints from my original answer remain, if the maximum voltage is reached. The controllers are not aware of the voltage limit, which can lead to integrator windup problems.

            Source https://stackoverflow.com/questions/58394269

            QUESTION

            How to fix "Model is not globally balanced" with SMPM and inverter
            Asked 2019-Sep-16 at 08:55

            Based on the example Modelica.Electrical.Machines.Examples.SynchronousInductionMachines.SMPM_VoltageSource, I am trying to use the inverter from Modelica.Electrical.PowerConverters.DCAC.MultiPhase2Level to feed the SMPM. Unfortunately I get the error

            Simulation model is not globally balanced, having 337 variables and 335 equations

            but I can't figure out which two equations are missing.

            What confuses me even more is that the model is balanced if I remove the signalPWM, inverter and the constantVoltage sources.

            ...

            ANSWER

            Answered 2019-Sep-12 at 09:22

            You vectorized the component componentsignalPWM, using m=3 instances. But only the first instance has its input connected.

            Change the connection

            Source https://stackoverflow.com/questions/57902981

            QUESTION

            Extracting 2D surface from 3D STEP model
            Asked 2019-Jul-07 at 03:22

            I'm trying to figure out a good way to programmatically generate contours describing a 2D surface, from a 3D STEP model. Application is generating NC code for a laser-cutting program from a 3D model.

            Note: it's easy enough to do this in a wide variety of CAD systems. I am writing software that needs to do it automatically.

            For example, this (a STEP model):

            Needs to become this (a vector file, like an SVG or a DXF):

            Perhaps the most obvious way of tackling the problem is to parse the STEP model and run some kind of algorithm to detect planes and select the largest as the cut surface, then generate the contour. Not a simple task!

            I've also considered using a pre-existing SDK to render the model using an orthographic camera, capture a high-res image, and then operating on it to generate the appropriate contours. This method would work, but it will be CPU-heavy, and its accuracy will be limited to the pixel resolution of the rendered image - not ideal.

            This is perhaps a long shot, but does anyone have thoughts about this? Cheers!

            ...

            ANSWER

            Answered 2019-Jul-07 at 03:22

            I would use a CAD library to load the STEP file (not a CAD API), look for the planar face with the higher number of edge curves in the face loop and transpose them on the XY plane. Afterward, finding 2D geometry min/max for centering etc. would be pretty easy.

            Depending on the programming language you are using I would search for "CAD control" or "CAD component" on Google combining it with "STEP import".

            Source https://stackoverflow.com/questions/53695096

            QUESTION

            Interpolating matrices with 2 variables and 1 dependent value
            Asked 2019-Apr-20 at 12:24

            I'm analyzing an induction motor, varying the frequency and absolute value of the stator current. Since the FEM-Tool only works with a current input, I need to vary the current over the frequency to obtain current-values of constant torque for each frequency.

            To generate a mesh, I use 2 for-loops: The outer loop sets the current. The inner loop varies the frequency with said current, gets the machine's torque and finally, the matrices are appended adding the current stator-current, frequency and torque each in separate matrices. Plotted it looks like this: Example of the plot using the raw data For the plot I used smaller, more imprecise matrices and rather arbitrary values:

            ...

            ANSWER

            Answered 2019-Apr-17 at 23:23

            Your data need to be in a meshgrid form, that is 2D:

            Source https://stackoverflow.com/questions/55736847

            QUESTION

            How to get WTForms to require entry into a RadioButton field?
            Asked 2019-Mar-21 at 17:38

            I'm creating a web form using Flask and Flask-WTF. The form is dynamic, with the fields determined by the database. Some questions in the database specify a radio button field, while others specify a single word.

            I need to require that the radio button fields have a selection. Using wtforms.validators.DataRequired works perfectly for the string fields, but not the radio fields.

            ...

            ANSWER

            Answered 2019-Mar-21 at 17:38

            I still don't know why DataRequired (and InputRequired) don't properly work with radio fields, but here's how I solved it.

            I subclassed FlaskForm as follows:

            Source https://stackoverflow.com/questions/55264876

            QUESTION

            Asp.net repeater databind on postback
            Asked 2018-Jun-12 at 07:00

            SOLUTION FOR FUTURE REFERENCE

            Problem was the "tecnico" variable that became 0 at every postback, also to avoid any problem I get rid of global variables data1 and data2 and moved them inside the Bindrepeater routine, like this:

            ...

            ANSWER

            Answered 2018-Jun-11 at 22:29

            I think your problem could be your global variables not preserving their new value after postback:

            Source https://stackoverflow.com/questions/50803019

            QUESTION

            How can I add in code to make it impossible for a user to input an answer that is not listed? C#
            Asked 2017-Nov-22 at 05:13
            using System;
            using System.Collections.Generic;
            using System.Linq;
            using System.Text;
            using System.Threading.Tasks;
            
                namespace Kenneth_ForquerENG_115
                {
                class Program
                {
                static void Main(string[] args)
                {
                    Console.WriteLine("Kenneth Forquer ENG 115");
            
            ...

            ANSWER

            Answered 2017-Nov-22 at 05:13

            One option would be to check if their answer is among the answer choices before checking if the answer is correct. You could do it like this:

            Source https://stackoverflow.com/questions/47426777

            QUESTION

            Using three in ECMA Script 6 STL Viewer class
            Asked 2017-Jul-24 at 16:37

            I am trying to convert a Three STL viewer demonstration into an ES6 Class which is then compiled with webpack 2 but i want it to open the file from URL rather than from an actual file input, ive managed to load the three components and most of the class is working but i think i am having problems in the scope with a few of the components, ive ran into a problem i dont seem to be able to get past when trying to use FileReader and then opening the scene and object. TypeError: Cannot read property 'remove' of undefined

            threeDimensionalModels.js ...

            ANSWER

            Answered 2017-Jul-24 at 16:37

            after a bit more playing around, and looking at the problem area, i realised that i was applying this to the global variable where this in the context i wanted did not exist, i would like to find a better way of passing this into child functions inside ECMA class functions without using a global variable

            update

            Source https://stackoverflow.com/questions/45284429

            QUESTION

            Selecting an element by its data-id attribute not working on all elements
            Asked 2017-Feb-23 at 14:11

            I am trying to select an element by its data-id attribute. The issue is that it is not working across all elements for some reason. For some reason, the script below will only work on items under the Rotor-Stator category and no other.

            Here is a sample of the HTML

            ...

            ANSWER

            Answered 2017-Feb-23 at 14:06

            Well because data-id="489 " has space in it just like a few others. Also format your HTML much more otherwise you're up for more problems!

            Source https://stackoverflow.com/questions/42417956

            Community Discussions, Code Snippets contain sources that include Stack Exchange Network

            Vulnerabilities

            No vulnerabilities reported

            Install stator

            The interactive CLI will guide you to easily setup your project.

            Support

            For any new features, suggestions and bugs create an issue on GitHub. If you have any questions check and ask questions on community page Stack Overflow .
            Find more information at:

            Find, review, and download reusable Libraries, Code Snippets, Cloud APIs from over 650 million Knowledge Items

            Find more libraries
            CLONE
          • HTTPS

            https://github.com/chocolat-chaud-io/stator.git

          • CLI

            gh repo clone chocolat-chaud-io/stator

          • sshUrl

            git@github.com:chocolat-chaud-io/stator.git

          • Stay Updated

            Subscribe to our newsletter for trending solutions and developer bootcamps

            Agree to Sign up and Terms & Conditions

            Share this Page

            share link