openr | Distributed platform for building autonomic network | Networking library
kandi X-RAY | openr Summary
kandi X-RAY | openr Summary
Open Routing, OpenR, is Facebook's internally designed and developed Interior Routing Protocol/Platform. OpenR was originally designed and built for performing routing on the Terragraph mesh network. OpenR's flexible design has led to its adoption in other networks, including Facebook's new WAN network, Express Backbone.
Support
Quality
Security
License
Reuse
Top functions reviewed by kandi - BETA
Currently covering the most popular Java, JavaScript and Python libraries. See a Sample of openr
openr Key Features
openr Examples and Code Snippets
Community Discussions
Trending Discussions on openr
QUESTION
I'm calculating the profit for each Pair
from List
and the count of its trades, as well as the BacktestResult
object itself because I need its properties, for ex. to print them. That's what the foreach
below does. I then want to receive the object of the maximum profit. The code works as expected but I want to recreate it entirely in LINQ, for ex. without that ugly Max() check. It should return var bestPair = BacktestResult object of the maximum result.Sum(e => e.ProfitPercentage)
.
ANSWER
Answered 2021-Jan-27 at 08:15You can try
QUESTION
I'm unable to parse the JSON file below to the corresponding class. It was exported by pandas' DateFrame. The reason I can't parse it, is because the format is a bit weird. How can I do that?
...ANSWER
Answered 2021-Jan-25 at 11:47The names of the BacktestResult class fields must be exactly the same as the json file fields.
QUESTION
The CalcTradePrice method should be called right after Trade object's initialization. Right now, it is being called before that, which leads to an exception:
...System.DivideByZeroException: 'Attempted to divide by zero.'
ANSWER
Answered 2021-Jan-21 at 14:43You can create parameterized constructor. Assign all properties through parameters passed to constructor.Use these properties to calculate trade price in CalcTradePrice()
function.
QUESTION
I'm using subprocess to run several scrapy spiders in parallel like this:
...ANSWER
Answered 2021-Jan-06 at 18:18This is not an error
This log line means that settings from scrapy default settings was replaced by
settings defined in settings.py
file from your project.
settings.py
value
AUTOTHROTTLE_ENABLED
False
True
AUTOTHROTTLE_START_DELAY
5.0
0.5
BOT_NAME
scrapybot
openrent
COOKIES_ENABLED
True
False
NEWSPIDER_MODULE
``
openrent.spiders
SPIDER_MODULES
[]
['openrent.spiders']
USER_AGENT
Scrapy/2.4 (+https://scrapy.org)
Safari/537.36
Without NEWSPIDER_MODULE
and SPIDER_MODULES
settings defined in your settings.py
scrapy will be unable to read your spider class.
QUESTION
I do not know much about cross-comping. I am using eclipse on linux machine to cross compile armv7-a Hellow world Example.
...ANSWER
Answered 2020-Nov-14 at 17:41It is important that the cross compiler and its settings fit the target setup where the application will be run. There is not enough information given here, but:
- arm-none-eabi is for bare-metal systems, i.e. no operating system is
involved or you are just compiling one. This means that the
environment may not provide the resources for the import
. There is just nothing to
to and you have to resort to the functionality base provided by the hardware vendor (e.g. writing your helloworld into a UART). If you are really developing such a system, it would be recommendable to use the provided hello world (or blinky) examples.
- If you are running linux-based system arm-linux-gnueabi or arm-elf may work
- a cortex-m3 runs on
march=armv7-m
QUESTION
I'm trying to use aggregation functions on a table to track the time progression of tasks assigned to users.
Part of the table looks something like this:
Table tasks
:
ANSWER
Answered 2020-Sep-22 at 12:28To get the result, you need to use subquery
and you can't use SELECT *
.
The following query using UNION SELECT
may be similar to what you said.
QUESTION
I have a simple Cordova project with Angular Framework. I am using https://github.com/auctifera-josed/cordova-plugin-idynamo plugin to communicate with MagTek device. I am listening to the 'magtekEvent'
on load of a particular screen to capture the data. Every time I go to other screen and come back to this screen I can see the event is triggering multiple times based on the number of time I visit this screen. I tried removing the event but nothing happened. Can anyone help me on how to stop this event when I go to other screen or when I close this device.
I added a log inside plugin file and found the plugin is triggering the event only once and I hope it can be fixed using JS itself.
Below is the code snippet:
...ANSWER
Answered 2020-Jul-31 at 10:49In order to deregister an event listener you need to pass exactly the same handler function that was used on the event listener registration.
So you can try to turn the event handler into a named function:
QUESTION
ANSWER
Answered 2020-Jun-25 at 19:37If you just want postcodes with no properties, use not exists
:
QUESTION
This is a very frustrating recurring problem. I only use flow rates in cubic meter per hour throughout my model. All Valve's flow rates are set dynamically, using various functions. Thus we use valve.set_openRate(flowm3h / 3.6)
to have flow in liter/sec and valve.set_openRate(flowm3h / 3600)
to have flow in cubic meter/sec.
However Anylogic seems to at random decide whether the set_openRate()
function uses units of liter/s or cubic_meter/s. For example I drop a valve Rate_when_open = openRate/3.6 liter/s and Initially closed
(using a parameter openRate). I set the parameter openRate = 1200. from here it goes to two fluid splits, splitting the fluid three ways. Each branch controlled via a valve - (outvalve_0 .. 2) no limits. Run the model, open outvalve_1, close it, open outvalve_0... all works fine; the flow rate is 0.333 (m3/s which is 333.33 liter/s, no problem). Save the model. Close Anylogic. Re-open Anylogic and load the model. Now modify the model, add a button and split the flow 0.2, 0.3 and 0.5 through the three valves, using a function outvalve_0.set_openRate(1200*0.2/3.6); outvalve_1.set_openRate(1200*0.3/3.6); outvalve_2.set_openRate(1200*0.5/3.6); outvalve_0.open();outvalve_1.open();outvalve_2.open();
Run. The flow is limited to 0.333 cubic meter/s and all flow goes out via outvalve_0. Run model in debug mode, it shows the openRate for outvalve_0 is set to 66.667 m3/s; outvalve_1 to 100 m3/s and outvalve_2 to 166.67 m3/s. Since the invalve limits flow to (1200/3.6) = 0.333 cubic meter/s, the rate on the three outvalves are too high (therefore Anylogic interpreted the initial (1200/3.6) as 0.333 m3/s and the subsequent (1200*0.2/3.6) as 66.67 m3/s and not as liter/s (0.067m3/s). You have to change the code to outvalve_0.set_openRate(1200*0.2/3600)..etc.
for it to work
Problem is this is not consequent. For in the next model, slightly different setup, if you use (1200*0.2/3600) it now interprets this as 0.000067 m3/s and you have to change the code back to (1200*0.2/3.6).
So the question: How do you know the units that Anylogic is going to use when you pass a flow-rate through the valve.set_openRate()
function? On what basis does it decide what the unit is? OR... Is there a way to force the unit?
ANSWER
Answered 2020-Jun-13 at 23:28I don't think AnyLogic is being inconsistent in the units it uses... Nevertheless from your description I would suggest this:
1) always use the units every time you change a rate or anything that requires units, in the case of set_openRate you can do
QUESTION
When using the mqtt callback function. I am getting extra characters and persisting characters on each run.
...ANSWER
Answered 2019-Jul-25 at 13:58You can't just cast the byte array payload
to a char array and then treat it as a string (a null terminated char array)
When you call Serial.println(msg)
println has no idea how long string is so will continue to read until it hits the first null it finds in memory. So far it sounds like you have got lucky and it's only been 1 or 2 bytes after the actual length of the incoming payload
byte array.
If you want a string that just contains the payload, you should malloc a new char array that is length
+ 1 and make sure the last char in the new array is set to 0 (null).
You should probably include the null terminator in your const strings as well that way strcmp will work properly as well.
Community Discussions, Code Snippets contain sources that include Stack Exchange Network
Vulnerabilities
No vulnerabilities reported
Install openr
If you make any changes you can run cmake ../openr and make from the build directory to build openr with your changes.
Support
Reuse Trending Solutions
Find, review, and download reusable Libraries, Code Snippets, Cloud APIs from over 650 million Knowledge Items
Find more librariesStay Updated
Subscribe to our newsletter for trending solutions and developer bootcamps
Share this Page