NModbus | NModbus is a C # implementation of the Modbus protocol | TCP library

 by   NModbus C# Version: 3.0.0-alpha1 License: MIT

kandi X-RAY | NModbus Summary

kandi X-RAY | NModbus Summary

NModbus is a C# library typically used in Networking, TCP applications. NModbus has no bugs, it has no vulnerabilities, it has a Permissive License and it has low support. You can download it from GitHub.

| |Build Status| |-----------|:----------:| |MS .NET|[Build status] NModbus is a C# implementation of the Modbus protocol. Provides connectivity to Modbus slave compatible devices and applications. Supports serial ASCII, serial RTU, TCP, and UDP protocols.
Support
    Quality
      Security
        License
          Reuse

            kandi-support Support

              NModbus has a low active ecosystem.
              It has 528 star(s) with 182 fork(s). There are 37 watchers for this library.
              OutlinedDot
              It had no major release in the last 6 months.
              There are 43 open issues and 65 have been closed. On average issues are closed in 144 days. There are 8 open pull requests and 0 closed requests.
              It has a neutral sentiment in the developer community.
              The latest version of NModbus is 3.0.0-alpha1

            kandi-Quality Quality

              NModbus has 0 bugs and 0 code smells.

            kandi-Security Security

              NModbus has no vulnerabilities reported, and its dependent libraries have no vulnerabilities reported.
              NModbus code analysis shows 0 unresolved vulnerabilities.
              There are 0 security hotspots that need review.

            kandi-License License

              NModbus is licensed under the MIT License. This license is Permissive.
              Permissive licenses have the least restrictions, and you can use them in most projects.

            kandi-Reuse Reuse

              NModbus releases are not available. You will need to build from source code and install.
              Installation instructions are not available. Examples and code snippets are available.
              It has 10 lines of code, 0 functions and 187 files.
              It has low code complexity. Code complexity directly impacts maintainability of the code.

            Top functions reviewed by kandi - BETA

            kandi's functional review helps you automatically verify the functionalities of the libraries and avoid rework.
            Currently covering the most popular Java, JavaScript and Python libraries. See a Sample of NModbus
            Get all kandi verified functions for this library.

            NModbus Key Features

            No Key Features are available at this moment for NModbus.

            NModbus Examples and Code Snippets

            No Code Snippets are available at this moment for NModbus.

            Community Discussions

            QUESTION

            How should I access these (Enron Modbus) registers?
            Asked 2021-Dec-07 at 15:02

            While using an OMNI Flow computer I ran into an issue I can't really wrap my head around. I'm trying to access 32 bits IEEE floating points number using NModbus.

            What I do to get one number :

            1. Read 2 registers using ReadHoldingRegisters(byte slaveAddress, ushort StartAddress, ushort numberOfPoints) with numberOfPoints = 2.
            2. Convert the 2 ushorts I read into 1 float like so :
            ...

            ANSWER

            Answered 2021-Dec-07 at 15:02

            After a few tests I have noticed that I am able to read the correct value from a register by using ReadHoldingRegisters(byte slaveAddress, ushort address, ushort numberOfPoints) with numberOfPoints = 2 while I get an error if I try with numberOfPoints = 1 because my device sends back 8 bytes of data instead of 4. This is coherent with the documentation stating that

            You cannot read or write a partial variable

            And since each floating point is in the form of a 32bits register I can't read less than 2 ushorts.

            Moreover, I discovered that, for me to read a value from a specific register (be it float or boolean) I had to use an address that was decremented by 1. So for example if I wanted to read the value in register 8080, in my code I should in fact read register 8079.

            I had a feeling there was an offset in the addressing but I wasn't expecting this.

            Source https://stackoverflow.com/questions/70247497

            QUESTION

            c# Nmodbus how to tcp slave
            Asked 2021-Mar-05 at 11:36

            I'm converting a project from NModbus4 to NModbus (since NModbus4 has last commit 5 years ago) but I can't find any modbus slave tcp implementation example so I'm stuck to this code and don't know how to get further. I'm searching for a solution all morning but

            ...

            ANSWER

            Answered 2021-Mar-05 at 11:36

            With this package I've managed to connect to Modbus RTU<->TCP converter that communicates with measuring device:

            https://www.nuget.org/packages/NModbus/

            Here you have some code samples that may be helpful (Especially from line 466):

            https://github.com/NModbus/NModbus/blob/develop/Samples/Program.cs

            I have tested one method for reading holding registers (but as master) and it seems to be working.

            Source https://stackoverflow.com/questions/66491256

            QUESTION

            Azure DevOps build cannot load referenced assemblies
            Asked 2020-Sep-08 at 16:30

            I've a .Net 4.7.6 solution with 400 projects. Some of those projects are referencing local DLL, some are using nugets packages.

            Everything is building fine on our VS, everything is building fine on our build machine(with MSBuild), but once we pushed everything on Azure DevOps, we have a bunch of referenced DLL(not all) that doesn't load:

            One example coming from package would be Log4Net:

            ...

            ANSWER

            Answered 2020-Sep-08 at 09:43

            What could be different regarding the loadable DLL between our VS Studio of the whole team and azure?

            When we deal with local dll files on Azure devops, we need to submit the those local dll files into the repo.

            And the HintPath in the project file for those local dll files should be relative path not absolute path.

            Last but not least, if you push dll files through git lfs to repo, in the Get Sources step there is a specific checkbox to enable git-lfs support. Without it the file will be replaced with a placeholder to the lfs download location:

            Update:

            we need to submit the those local dll files into the repo. what do you mean by that? All DLL are on our git(I mean, on a brand new computer with visual studio, I can checkout the code and build, no need to install anything else). Also, we use Azure Repository, so we don't have GUI steps, and I've no Get Sources step in the template that has been generated

            I mean if we use those local dll files with Azure pipeline, we need submit those dll files with our projects to the Azure devops repo. When we create a build pipeline, we will select the build source, then Azure devops pipeline will checkout the build source to the build agent:

            The code source could be Azure devops repo, Github, Github Enterprise server, Bitucket cloud. If you select the Azure devops repo as code source, we need submit and push those dll files to the Azure devops repo.

            Next, when you open your build pipeline (YAML), and click the three vertical dots, select the Triggers and switch to YAML tab, you will see the get source:

            Source https://stackoverflow.com/questions/63787918

            Community Discussions, Code Snippets contain sources that include Stack Exchange Network

            Vulnerabilities

            No vulnerabilities reported

            Install NModbus

            You can download it from GitHub.

            Support

            For any new features, suggestions and bugs create an issue on GitHub. If you have any questions check and ask questions on community page Stack Overflow .
            Find more information at:

            Find, review, and download reusable Libraries, Code Snippets, Cloud APIs from over 650 million Knowledge Items

            Find more libraries
            CLONE
          • HTTPS

            https://github.com/NModbus/NModbus.git

          • CLI

            gh repo clone NModbus/NModbus

          • sshUrl

            git@github.com:NModbus/NModbus.git

          • Stay Updated

            Subscribe to our newsletter for trending solutions and developer bootcamps

            Agree to Sign up and Terms & Conditions

            Share this Page

            share link

            Explore Related Topics

            Consider Popular TCP Libraries

            masscan

            by robertdavidgraham

            wait-for-it

            by vishnubob

            gnet

            by panjf2000

            Quasar

            by quasar

            mumble

            by mumble-voip

            Try Top Libraries by NModbus

            NModbus.Tools

            by NModbusC#

            NModbus.github.io

            by NModbusHTML

            NModbusNext

            by NModbusC#