QUESTION
I'm trying to investigate the Modelica example Modelica.Electrical.Machines.Examples.SynchronousInductionMachines.SMPM_VoltageSource
but I replaced the signalVoltage
by an inverter and a PWM block signalPWM
which is based on Modelica.Electrical.PowerConverters.DCDC.Control.SignalPWM
. So instead of sine voltages I want to investigate PWM modulated voltages.
The problem is that the controller keeps increasing its output linearily because of the integrating part of the controller as it never reaches the reference value of the desired q-current. In addition it outputs strange values for voltageController.y[1]
in the range of [24E3,...,150E3], which is probrably the problem.
Unfortunately I don't understand why the controller works fine with the sine voltages and doesnt with the PWM voltages.
Below is my main model:
...ANSWER
Answered 2019-Nov-06 at 09:41With a voltage of ±200V and a load of 120Nm its simply not possible to obtain the demanded currents.
In contrast to the original MSL example you use a sign torque with 120Nm as load.
If you use that in the original MSL example, you will notice that the machine
keeps accelerating and that the required voltage grows without bounds (plot e.g. smpm.plug_sp.pin[1].v
to see that).
In your example the voltage is limited to 200V. The demanded currents of -53A and 84.6A are not obtained, but the machine still generates a torque of 127Nm, which lets the machine accelerate. With increasing speed the required voltages increase also for a certain torque / current demand - but in your example the actual voltage is limited. Therefore the set currents are never reached.
What you can consider:
- increase the available voltage
(but for the current setup you need unrealistic high values of several thousand volts) - demand lower currents
(You can setId
on 0 anyway, as you have a machine withLd=Lq
, so onlyIq
produces torque andId
is used for field weakening) - make your current controllers aware of the voltage limit
(use e.g.Modelica.Blocks.Continuous.LimPID
for that, which contains anti-windup already)
The problem lies in your PWM computation.
I rebuilt the example with the original SignalPWM
block from the MSL and a VoltageToDutyCycle
component.
In the screenshot below the simulation results of the new model with f=14kHz are compared with the MSL version with ideal voltage supply. The screenshot shows the controller output (like in your question) and Iq.
The results were computed with the package below. It contains
- a partial model for all common components and variables
- an example with PWM and inverter
- an example with ideal continuous voltage supply
Note that the hints from my original answer remain, if the maximum voltage is reached. The controllers are not aware of the voltage limit, which can lead to integrator windup problems.
QUESTION
Based on the example Modelica.Electrical.Machines.Examples.SynchronousInductionMachines.SMPM_VoltageSource
, I am trying to use the inverter from Modelica.Electrical.PowerConverters.DCAC.MultiPhase2Level
to feed the SMPM.
Unfortunately I get the error
Simulation model is not globally balanced, having 337 variables and 335 equations
but I can't figure out which two equations are missing.
What confuses me even more is that the model is balanced if I remove the signalPWM
, inverter
and the constantVoltage
sources.
ANSWER
Answered 2019-Sep-12 at 09:22You vectorized the component componentsignalPWM
, using m=3
instances. But only the first instance has its input connected.
Change the connection
QUESTION
I'm using SystemModeler from Wolfram to investigate the system behaviour of an inverter connected to a permanent magnet synchronous machine. Unfortunately I get wrong simulation results eventhough I only used components from the Modelica Standard Library.
I tried several settings so far with my model below.
...ANSWER
Answered 2019-Sep-09 at 15:17What you are trying to do in you model is, to let a synchronous machine operate at nominal electrical frequency directly from standstill. This will make the machine "fall out of step", which is the reason for the machine not to operate as you would expect, but just oscillate in a seemingly random manner.
Try to reduce sine[*].freqHz
to fill(0.01*f1, m)
and you will see that there it will - after some oscillations - start to operate at one percent of its nominal frequency. It's just that the machine cannot overcome the oscillations for the jump to the nominal frequency.
There are multiple possibilities to work around that issue:
- Initialize the machine properly: This can be done by setting at least
smpm.wMechancial.start
andsmpm.phiMechancial.start
to the correct values. Additionally it would be good to also initialize the phase currents correctly. This can be pretty tedious to do. But gives the advantage that you don't have to ramp up the speed. - It's likely easier to copy parts of the example
Modelica.Electrical.Machines.Examples.SynchronousInductionMachines.SMPM_Inverter
, where a voltage-frequency-controller is used to start the machine. - Many synchronous machines are actually controlled (e.g. by field-orientation or direct-torque control). For this some clues can be taken from
Modelica.Electrical.Machines.Examples.SynchronousInductionMachines.SMPM_CurrentSource
andModelica.Electrical.Machines.Examples.SynchronousInductionMachines.SMPM_VoltageSource
.
Additionally I would suggest to first try to get your example running with a continuous inverter like in Modelica.Electrical.Machines.Examples.SynchronousInductionMachines.SMPM_Inverter
. If that works asexpected, move on the switched one.
Some things that look suspicious to me:
smpm.Rs
seems pretty big to me with 4.7 Ohms especially when considering the inertiassmpm.Jr
(with 0.29 kg.m2) andinertia1.J
(with 0.29 kg.m2).- For testing, try to increase the switching frequency above 1kHz. This is a bit low for a fundamental wave frequency of 50Hz (although it should work).
QUESTION
relatively new to AWK here. Wanting to compare two files. First two columns are to match in order to compare the 3rd column. 3rd column needs to be 100 larger in order to print that line from the second file. Some data may exist in one file but not in the other. I don't think it matters to AWK, but spaceing isn't very consistent for delimination. Here is a small snipit.
File1
...ANSWER
Answered 2018-Oct-23 at 21:16you need to key the value with the same ($1,$2) combination. Since we don't use a
for any other purposes just store the value there.
QUESTION
This is my xml file:
...ANSWER
Answered 2018-Aug-09 at 14:35XmlSerializer serializer = new XmlSerializer(typeof(List));
using(FileStream stream = File.OpenWrite("filename"))
{
List list = new List();
serializer.Serialize(stream, list);
}
using(FileStream stream = File.OpenRead("filename"))
{
List dezerializedList = (List)serializer.Deserialize(stream);
}
QUESTION
I need tome assistance with an SQL query in DB2 using QMF for Qrkstation z/OS V11.1 Fix Pack 3.
I am querying a couple of fields from different tables. I am showing some timestamps too. I need a CASE clause which uses one of those timestamps.
The idea is that one of the timestamps can have data or not (null) because I am using LEFT JOIN with that table (if value then bring it if not then blank) So the CASE clause would need to check that column/field and if it has data (IS NOT NULL) then put value 'Delivered'. This logic is no working for me as seen in the following images.
...ANSWER
Answered 2018-Mar-02 at 20:29I think the main issue is that you are selecting the maximum value returned by the case statement for each id rather than the value of the CAS Statement for the maximum date. So the order of those values is (On time CAD, Non physical, More than 10 days..., Less than 3 days..., Delivered, Between 6..., Between 3). So if all those id's had a record where ship_evnt_tms
was null, the max vbalue coming out of that case will be More than 10 days...
. It is also strange that you are using distinct with aggregation. Instead you could just group on po_id
. Maybe try:
QUESTION
I have the following query in DB2 for which I need to combine the rows with values with the ones with nulls into a single line, eventually removing the nulls when there is valid data for that column.
The SQL is
...ANSWER
Answered 2018-Mar-01 at 23:07Just use aggregation:
Community Discussions, Code Snippets contain sources that include Stack Exchange Network
Vulnerabilities
No vulnerabilities reported
Install dcdc
Support
Reuse Trending Solutions
Find, review, and download reusable Libraries, Code Snippets, Cloud APIs from over 650 million Knowledge Items
Find more librariesStay Updated
Subscribe to our newsletter for trending solutions and developer bootcamps
Share this Page